Filter products

Steca PA 15
Steca PA 15 The Steca Tarom and Power Tarom charge controllers send out signals (125 kHz on 300 Baud) which are modulated on the DC cable and received by the Steca PA 15 remote control.These signals contain information on the batteries' state of charge (SOC). The Steca PA 15 features five different operating modes (see below) which can be set using five different jumper positions. The maximum switching capacity of 15 A can be increased with a Steca PA EV200 DC relay to up to 200 A if desired. Product features Receives information on SOC and time (day/night) Load control via priority assignment Adjustable SOC thresholds Connects a maximum of 9 solar arrays in parallel Current surge switch function Electronic protection functions Switches off load if there is no signal Reverse polarity protection by internal fuse Overtemperature and overload protection Operation Configuration by jumpers Modes of operation Management of parallel solar generators When the battery is full, excess energy is redirected to additional loads such as pumps, water heaters Automatic start / stop of diesel or wind back-up generators Night light function Acoustic alarm at deep discharge or overheating

Steca PA CAB1
Steca PA CAB1 Tarcom Steca data cables are used to connect the Steca Tarom and Steca Power Tarom solar charge controllers to a PC via a USB port. This allows direct monitoring of a system without using a data logger. This feature is especially suitable for short-term system monitoring and on-site testing. The most important system information is transferred to the PC in real time and can be conveniently analysed and graphically visualised using the Steca TarCom software.To use this convenient data transfer system a driver and the Steca TarCom software must first be installed on the PC (Download available at www.stecasolar.com).„Tarom RJ45 in“ can be selected under options/settings/extra in the Steca TarCom software menu system. The software then directly accesses the data from the Steca Power Tarom solar charge controller and displays this on the PC.

Steca PA CAB2
Steca PA CAB2 Tarcom Steca data cables are used to connect the Steca Tarom and Steca Power Tarom solar charge controllers to a PC via a USB port. This allows direct monitoring of a system without using a data logger. This feature is especially suitable for short-term system monitoring and on-site testing. The most important system information is transferred to the PC in real time and can be conveniently analysed and graphically visualised using the Steca TarCom software.To use this convenient data transfer system a driver and the Steca TarCom software must first be installed on the PC (Download available at www.stecasolar.com).„Tarom RJ45 in“ can be selected under options/settings/extra in the Steca TarCom software menu system. The software then directly accesses the data from the Steca Power Tarom solar charge controller and displays this on the PC.

Steca PA EV 200 Typ B 36/48V
Steca PA EV 200 Typ B 36/48V The Steca PA EV200 relay increases the switching capacity of the Steca PA 15 remote control from 15 A to 200 A (up to 10 kW). The relay is connected to the Steca PA 15 remote control at the load output and, for example, interrupts the battery voltage to a back-up generator when the end-of-charge voltage is reached. The relay is hermetically sealed and operates safely in difficult environmental conditions such as dust, salt and moisture. Product features Low own consumption Ready for connection to the Steca PA 15 remote control

Steca PA HS 200
Steca PA HS 200 The Steca PA HS200/400 is a highly intelligent current sensor with extremely low own consumption.The Steca PA HS200/400 is a highly intelligent current sensor with extremely low own consumption.The Steca PA HS200/400 comes into play when (e.g.) an inverter is directly connected to the battery and the charge controller cannot measure the current consumption. A shunt is also required when an additional generator (e.g. PV, wind or diesel) directly charges the battery. The current is measured contact-free via a Hall-effect sensor. The data is transmitted to the charge controller over a cable connection. All types of current flows can be detected: charge current, load current and battery and DC-side inverter current flows.The Steca PA HS200 has been developed for applications with the Steca Power Tarom. The PA HS400 can be used exclusively with the Steca Tarom MPPT 6000-M.

Steca PA IRS 1008/180 12V
Steca PA IRS 1008/180 12V Motion detector The Steca PA IRS 1008/180 motion detector is connected to the load output of the night light charge controller. This supplies power to the light, which is then turned on for a few minutes when some movement is detected.The Steca PA IRS 1008/180 stands out, above all, with its extremely low own consumption, and is therefore optimal for use in solar power systems.

Steca PA IRS 1008/180 24V
Steca PA IRS 1008/180 24V Motion detector The Steca PA IRS 1008/180 motion detector is connected to the load output of the night light charge controller. This supplies power to the light, which is then turned on for a few minutes when some movement is detected.The Steca PA IRS 1008/180 stands out, above all, with its extremely low own consumption, and is therefore optimal for use in solar power systems.

Steca PA RC100
Steca PA RC100 Steca PA RC100 remote control allows to program Steca solar charge controllers. The values can be adjusted with the help of switches. After a restart of the charge controller the new settings can be activated by pressing the program-button on the Steca PA RC100. An LED will transfer the values to the controller.

Steca PA Tarcom 01
Steca PA Tarcom 01 The Steca PA Tarcom data logger is connected to the RJ45 interface of the Steca Power Tarom charge controller, or via the Steca PA HS200.The data logger is available in several different versions: as a simple RS232 interface to directly save and read data on the PC or Laptop (Steca PA Tarcom 01), as a data logger with an integrated analogue modem (Steca PA Tarcom RMT), as a data logger with an integrated GSM modem for remote monitoring (Steca PA Tarcom GSM) and as a data logger with an Ethernet interface for connection to a PC network (Steca PA Tarcom Ethernet). The Steca PA Tarcom is delivered with its accompanying software. Product features 4 years maximum storage capacity (1 Mbit) Adjustable logging intervals Stores 8 data sets at programmed intervals Freely programmable alarm states Displays LED shows operating states Interfaces RJ45 communication interface to Steca Power Tarom RS232 serial interface to PC Analogue sensor input e.g. for radiation or wind speed Alarm contact Tarcom software Data transfer by modem or by text message Downloads data from the logger to a PC List of data sets can be exported to MS-EXCEL Graphic visualisation of data sets (values/time) Analyzes energy flows (Ah) within a PV hybrid system Activation and selection of alarm types Setting the interval for calls and for sending text messages Configures the telephone number and text message recipient Tells the data logger at what time it has to call Alarms can be set by text message Certificates Compliant with European Standards (CE) Made in Germany Developed in Germany

Steca PA Tarcom Ethernet
Steca PA Tarcom Ethernet The Steca PA Tarcom data logger is connected to the RJ45 interface of the Steca Power Tarom charge controller, or via the Steca PA HS200.The data logger is available in several different versions: as a simple RS232 interface to directly save and read data on the PC or Laptop (Steca PA Tarcom 01), as a data logger with an integrated analogue modem (Steca PA Tarcom RMT), as a data logger with an integrated GSM modem for remote monitoring (Steca PA Tarcom GSM) and as a data logger with an Ethernet interface for connection to a PC network (Steca PA Tarcom Ethernet). The Steca PA Tarcom is delivered with its accompanying software. Product features 4 years maximum storage capacity (1 Mbit) Adjustable logging intervals Stores 8 data sets at programmed intervals Freely programmable alarm states Displays LED shows operating states Interfaces RJ45 communication interface to Steca Power Tarom RS232 serial interface to PC Analogue sensor input e.g. for radiation or wind speed Alarm contact Tarcom software Data transfer by modem or by text message Downloads data from the logger to a PC List of data sets can be exported to MS-EXCEL Graphic visualisation of data sets (values/time) Analyzes energy flows (Ah) within a PV hybrid system Activation and selection of alarm types Setting the interval for calls and for sending text messages Configures the telephone number and text message recipient Tells the data logger at what time it has to call Alarms can be set by text message Certificates Compliant with European Standards (CE) Made in Germany Developed in Germany

Steca PA Tarcom GSM
Steca PA Tarcom GSM The Steca PA Tarcom data logger is connected to the RJ45 interface of the Steca Power Tarom charge controller, or via the Steca PA HS200.The data logger is available in several different versions: as a simple RS232 interface to directly save and read data on the PC or Laptop (Steca PA Tarcom 01), as a data logger with an integrated analogue modem (Steca PA Tarcom RMT), as a data logger with an integrated GSM modem for remote monitoring (Steca PA Tarcom GSM) and as a data logger with an Ethernet interface for connection to a PC network (Steca PA Tarcom Ethernet). The Steca PA Tarcom is delivered with its accompanying software. Product features 4 years maximum storage capacity (1 Mbit) Adjustable logging intervals Stores 8 data sets at programmed intervals Freely programmable alarm states Displays LED shows operating states Interfaces RJ45 communication interface to Steca Power Tarom RS232 serial interface to PC Analogue sensor input e.g. for radiation or wind speed Alarm contact Tarcom software Data transfer by modem or by text message Downloads data from the logger to a PC List of data sets can be exported to MS-EXCEL Graphic visualisation of data sets (values/time) Analyzes energy flows (Ah) within a PV hybrid system Activation and selection of alarm types Setting the interval for calls and for sending text messages Configures the telephone number and text message recipient Tells the data logger at what time it has to call Alarms can be set by text message Certificates Compliant with European Standards (CE) Made in Germany Developed in Germany

Steca PA Tarcom RM / RMT
Steca PA Tarcom RM / RMT The Steca PA Tarcom data logger is connected to the RJ45 interface of the Steca Power Tarom charge controller, or via the Steca PA HS200.The data logger is available in several different versions: as a simple RS232 interface to directly save and read data on the PC or Laptop (Steca PA Tarcom 01), as a data logger with an integrated analogue modem (Steca PA Tarcom RMT), as a data logger with an integrated GSM modem for remote monitoring (Steca PA Tarcom GSM) and as a data logger with an Ethernet interface for connection to a PC network (Steca PA Tarcom Ethernet). The Steca PA Tarcom is delivered with its accompanying software. Product features 4 years maximum storage capacity (1 Mbit) Adjustable logging intervals Stores 8 data sets at programmed intervals Freely programmable alarm states Displays LED shows operating states Interfaces RJ45 communication interface to Steca Power Tarom RS232 serial interface to PC Analogue sensor input e.g. for radiation or wind speed Alarm contact Tarcom software Data transfer by modem or by text message Downloads data from the logger to a PC List of data sets can be exported to MS-EXCEL Graphic visualisation of data sets (values/time) Analyzes energy flows (Ah) within a PV hybrid system Activation and selection of alarm types Setting the interval for calls and for sending text messages Configures the telephone number and text message recipient Tells the data logger at what time it has to call Alarms can be set by text message Certificates Compliant with European Standards (CE) Made in Germany Developed in Germany

Steca PA TS-S
Steca PA TS-S The Steca PA TS10, Steca PA TSIP10 and Steca PA TS-S external temperature sensors are used for monitoring the battery temperature.All Steca solar charge controllers have an integrated temperature sensor that makes them capable of adjusting the charging strategy to suit the current temperature conditions. The external temperature sensors are only required when the battery must be installed in a different room to the solar charge controller.The Steca PA TS10 and Steca PA TSIP10 are supplied with a plug for connection to the solar charge controller and ring eyelets for connection to the battery screw.The external temperature sensors are suitable for use with Steca PR 10-30, Steca Solarix MPPT, Steca PR 2020 IP, Steca Tarom 4545 and Steca Tarom MPPT 6000 solar charge controllers.

Steca PA TS10
Steca PA TS10 The Steca PA TS10, Steca PA TSIP10 and Steca PA TS-S external temperature sensors are used for monitoring the battery temperature.All Steca solar charge controllers have an integrated temperature sensor that makes them capable of adjusting the charging strategy to suit the current temperature conditions. The external temperature sensors are only required when the battery must be installed in a different room to the solar charge controller.The Steca PA TS10 and Steca PA TSIP10 are supplied with a plug for connection to the solar charge controller and ring eyelets for connection to the battery screw.The external temperature sensors are suitable for use with Steca PR 10-30, Steca Solarix MPPT, Steca PR 2020 IP, Steca Tarom 4545 and Steca Tarom MPPT 6000 solar charge controllers.